{"id":1409,"date":"2021-01-13T11:06:18","date_gmt":"2021-01-13T15:06:18","guid":{"rendered":"https:\/\/cyburityllc.com\/?p=1409"},"modified":"2023-10-29T16:48:48","modified_gmt":"2023-10-29T20:48:48","slug":"how-to-set-proper-answering-machine-detection-settings-for-vicibox9-10","status":"publish","type":"post","link":"https:\/\/dialer.one\/index.php\/how-to-set-proper-answering-machine-detection-settings-for-vicibox9-10\/","title":{"rendered":"How to &#8211; Set proper Answering Machine Detection settings for Vicibox9\/10"},"content":{"rendered":"\n<h1 class=\"wp-block-heading\">How to &#8211; Set proper Answering Machine Detection settings for Vicibox v9\/10\/11<\/h1>\n\n\n\n<h2 class=\"wp-block-heading\">Working settings for AMD on Vicibox v9, 10 or 11 or any scratch install<\/h2>\n\n\n\n<p>Everyone seems to not like the AMD settings for Vicibox9, but the problem is, they are used to a simpler format from earlier versions that don&#8217;t have the functionality of the newer SVN versions. Below are the settings that I use that seem to work.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Campaign Detail Settings<\/h3>\n\n\n\n<p>Change the WaitForSilence to 2000,2,30 and AMD Agent Route to enabled and AMD Type to AMD<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" src=\"https:\/\/cyburityllc.com\/wp-content\/uploads\/2021\/01\/image-1-1024x423.png\" alt=\"\" class=\"wp-image-1410\" style=\"width:723px;height:298px\" width=\"723\" height=\"298\" title=\"\" srcset=\"https:\/\/dialer.one\/wp-content\/uploads\/2021\/01\/image-1-1024x423.png 1024w, https:\/\/dialer.one\/wp-content\/uploads\/2021\/01\/image-1-600x248.png 600w, https:\/\/dialer.one\/wp-content\/uploads\/2021\/01\/image-1-300x124.png 300w, https:\/\/dialer.one\/wp-content\/uploads\/2021\/01\/image-1-768x318.png 768w, https:\/\/dialer.one\/wp-content\/uploads\/2021\/01\/image-1-500x207.png 500w, https:\/\/dialer.one\/wp-content\/uploads\/2021\/01\/image-1-800x331.png 800w, https:\/\/dialer.one\/wp-content\/uploads\/2021\/01\/image-1.png 1069w\" \/><figcaption class=\"wp-element-caption\">Change AMD Type to AMD, AMD Agent Route options to Enabled and WaitForSilence<\/figcaption><\/figure>\n<\/div>\n\n\n<h3 class=\"wp-block-heading\">Containing Settings<\/h3>\n\n\n\n<p>Go to Admin &gt; Settings Container &gt;<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" src=\"https:\/\/cyburityllc.com\/wp-content\/uploads\/2021\/01\/image-2-1024x523.png\" alt=\"\" class=\"wp-image-1412\" style=\"width:730px;height:372px\" width=\"730\" height=\"372\" title=\"\" srcset=\"https:\/\/dialer.one\/wp-content\/uploads\/2021\/01\/image-2-1024x523.png 1024w, https:\/\/dialer.one\/wp-content\/uploads\/2021\/01\/image-2-600x306.png 600w, https:\/\/dialer.one\/wp-content\/uploads\/2021\/01\/image-2-300x153.png 300w, https:\/\/dialer.one\/wp-content\/uploads\/2021\/01\/image-2-768x392.png 768w, https:\/\/dialer.one\/wp-content\/uploads\/2021\/01\/image-2-500x255.png 500w, https:\/\/dialer.one\/wp-content\/uploads\/2021\/01\/image-2-800x408.png 800w, https:\/\/dialer.one\/wp-content\/uploads\/2021\/01\/image-2.png 1189w\" \/><\/figure>\n<\/div>\n\n\n<p>Click on the AMD_AGENT_OPT_Campaign you want to change<a href=\"https:\/\/ibb.co\/Y249CPY\" target=\"_blank\" rel=\"noopener\"><\/a><\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/cyburityllc.com\/wp-content\/uploads\/2021\/01\/settingscontainer-AMD.png\" alt=\"\" class=\"wp-image-1411\" style=\"width:727px;height:293px\" width=\"727\" height=\"293\" title=\"\" srcset=\"https:\/\/dialer.one\/wp-content\/uploads\/2021\/01\/settingscontainer-AMD.png 702w, https:\/\/dialer.one\/wp-content\/uploads\/2021\/01\/settingscontainer-AMD-600x243.png 600w, https:\/\/dialer.one\/wp-content\/uploads\/2021\/01\/settingscontainer-AMD-300x121.png 300w, https:\/\/dialer.one\/wp-content\/uploads\/2021\/01\/settingscontainer-AMD-500x202.png 500w\" sizes=\"auto, (max-width: 727px) 100vw, 727px\" \/><figcaption class=\"wp-element-caption\">Add the lines to your container as shown<\/figcaption><\/figure>\n<\/div>\n\n\n<p>Hopefully this helps a lot of you that have been experiencing this problem.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>How to &#8211; Set proper Answering Machine Detection settings for Vicibox v9\/10\/11 Working settings for AMD on Vicibox v9, 10 or 11 or any scratch install Everyone seems to not like the AMD settings for Vicibox9, but the problem is, they are used to a simpler format from earlier versions that don&#8217;t have the functionality [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":1412,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"content-type":"","_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_publicize_message":"","jetpack_publicize_feature_enabled":true,"jetpack_social_post_already_shared":true,"jetpack_social_options":{"image_generator_settings":{"template":"highway","default_image_id":0,"font":"","enabled":false},"version":2}},"categories":[96],"tags":[],"class_list":["post-1409","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-vicidial"],"jetpack_publicize_connections":[],"jetpack_featured_media_url":"https:\/\/dialer.one\/wp-content\/uploads\/2021\/01\/image-2.png","jetpack-related-posts":[{"id":1706,"url":"https:\/\/dialer.one\/index.php\/why-doesnt-my-vicibox9-iso-install-work\/","url_meta":{"origin":1409,"position":0},"title":"Why doesn&#8217;t my Vicibox9 ISO install work?","author":"carpenox","date":"March 19, 2021","format":false,"excerpt":"Why doesn't my Vicibox9 ISO install work? Well, it seems there is an issue with the installer now since Leap 15.1 went end of life and no longer supports updates. So what do you do now? A scratch install on Leap 15.2 is one option following a post I wrote\u2026","rel":"","context":"With 2 comments","block_context":{"text":"With 2 comments","link":"https:\/\/dialer.one\/index.php\/why-doesnt-my-vicibox9-iso-install-work\/#comments"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/dialer.one\/wp-content\/uploads\/2021\/03\/zypperupleap152.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/dialer.one\/wp-content\/uploads\/2021\/03\/zypperupleap152.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/dialer.one\/wp-content\/uploads\/2021\/03\/zypperupleap152.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/dialer.one\/wp-content\/uploads\/2021\/03\/zypperupleap152.png?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":2378,"url":"https:\/\/dialer.one\/index.php\/table-of-contents\/","url_meta":{"origin":1409,"position":1},"title":"Table of Contents &#8211; Knowledge Base","author":"carpenox","date":"March 7, 2022","format":false,"excerpt":"Welcome to my blog, some of you may know me from the ViciDial forums, I am carpenox and I am here to share my knowledge with everyone, for free!","rel":"","context":"In &quot;Vicidial&quot;","block_context":{"text":"Vicidial","link":"https:\/\/dialer.one\/index.php\/category\/vicidial\/"},"img":{"alt_text":"CyburDial","src":"https:\/\/i0.wp.com\/dialer.one\/wp-content\/uploads\/2022\/02\/image.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/dialer.one\/wp-content\/uploads\/2022\/02\/image.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/dialer.one\/wp-content\/uploads\/2022\/02\/image.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/dialer.one\/wp-content\/uploads\/2022\/02\/image.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/dialer.one\/wp-content\/uploads\/2022\/02\/image.png?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":3768,"url":"https:\/\/dialer.one\/index.php\/how-to-setup-a-press-1-campaign-in-vicidial\/","url_meta":{"origin":1409,"position":2},"title":"How to &#8211; Setup a Press 1 campaign in ViciDial","author":"carpenox","date":"October 21, 2023","format":false,"excerpt":"How to - Setup a Press 1 campaign in ViciDial In this article I will cover how to setup a press 1 campaign in ViciDial. I am in no way a lawyer, however you should know that press 1 campaigns in the US is illegal to customers unless you have\u2026","rel":"","context":"In &quot;Vicidial&quot;","block_context":{"text":"Vicidial","link":"https:\/\/dialer.one\/index.php\/category\/vicidial\/"},"img":{"alt_text":"Press 1 campaign","src":"https:\/\/i0.wp.com\/dialer.one\/wp-content\/uploads\/2023\/10\/image-7.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/dialer.one\/wp-content\/uploads\/2023\/10\/image-7.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/dialer.one\/wp-content\/uploads\/2023\/10\/image-7.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/dialer.one\/wp-content\/uploads\/2023\/10\/image-7.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/dialer.one\/wp-content\/uploads\/2023\/10\/image-7.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/dialer.one\/wp-content\/uploads\/2023\/10\/image-7.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":1765,"url":"https:\/\/dialer.one\/index.php\/how-to-use-the-built-in-dynamic-portal-for-vicibox\/","url_meta":{"origin":1409,"position":3},"title":"How to &#8211; Use the built in Dynamic Portal for Vicibox","author":"carpenox","date":"March 31, 2021","format":false,"excerpt":"How to - Use the built in Dynamic Portal for Vicibox Ok so I have had a LOT of people ask me how to use the dynamic portal for Vicibox or for their own Vicidial scratch install. I didn't think I needed to go over this topic, since it's in\u2026","rel":"","context":"With 2 comments","block_context":{"text":"With 2 comments","link":"https:\/\/dialer.one\/index.php\/how-to-use-the-built-in-dynamic-portal-for-vicibox\/#comments"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/dialer.one\/wp-content\/uploads\/2021\/03\/image-11.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/dialer.one\/wp-content\/uploads\/2021\/03\/image-11.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/dialer.one\/wp-content\/uploads\/2021\/03\/image-11.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/dialer.one\/wp-content\/uploads\/2021\/03\/image-11.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/dialer.one\/wp-content\/uploads\/2021\/03\/image-11.png?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":2394,"url":"https:\/\/dialer.one\/index.php\/how-to-setup-a-vicidial-cluster\/","url_meta":{"origin":1409,"position":4},"title":"How to &#8211; Setup a ViciDial Cluster","author":"carpenox","date":"March 12, 2022","format":false,"excerpt":"How to - Setup a ViciDial Cluster This article is going to go over the steps I suggest to take in order to setup a ViciDial Cluster. I do things a little different when it comes to this to prepare for worst case scenario that a server may have problems\u2026","rel":"","context":"In &quot;CyburDial&quot;","block_context":{"text":"CyburDial","link":"https:\/\/dialer.one\/index.php\/category\/cyburdial\/"},"img":{"alt_text":"ViciDial Cluster","src":"https:\/\/i0.wp.com\/dialer.one\/wp-content\/uploads\/2022\/03\/image-4.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/dialer.one\/wp-content\/uploads\/2022\/03\/image-4.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/dialer.one\/wp-content\/uploads\/2022\/03\/image-4.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/dialer.one\/wp-content\/uploads\/2022\/03\/image-4.png?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":1174,"url":"https:\/\/dialer.one\/index.php\/vicidial-error-code-expects-different-schema\/","url_meta":{"origin":1409,"position":5},"title":"How to &#8211; Fix the Vicidial error: Code Expects Different Schema","author":"carpenox","date":"October 18, 2020","format":false,"excerpt":"How to - Fix the Vicidial error: Code Expects Different Schema This is a pretty easy fix, \"Code Expects Different Schema\" occurs when you update your svn version but forget to update the db schema through mysql. The instructions are below. different schema After database dump restoration taken from older\u00a0Vicibox\u00a0to\u2026","rel":"","context":"With 1 comment","block_context":{"text":"With 1 comment","link":"https:\/\/dialer.one\/index.php\/vicidial-error-code-expects-different-schema\/#comments"},"img":{"alt_text":"different schema","src":"https:\/\/i0.wp.com\/dialer.one\/wp-content\/uploads\/2020\/10\/dbschema.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/dialer.one\/wp-content\/uploads\/2020\/10\/dbschema.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/dialer.one\/wp-content\/uploads\/2020\/10\/dbschema.png?resize=525%2C300&ssl=1 1.5x"},"classes":[]}],"jetpack_likes_enabled":true,"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/dialer.one\/index.php\/wp-json\/wp\/v2\/posts\/1409","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/dialer.one\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/dialer.one\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/dialer.one\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/dialer.one\/index.php\/wp-json\/wp\/v2\/comments?post=1409"}],"version-history":[{"count":0,"href":"https:\/\/dialer.one\/index.php\/wp-json\/wp\/v2\/posts\/1409\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/dialer.one\/index.php\/wp-json\/wp\/v2\/media\/1412"}],"wp:attachment":[{"href":"https:\/\/dialer.one\/index.php\/wp-json\/wp\/v2\/media?parent=1409"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/dialer.one\/index.php\/wp-json\/wp\/v2\/categories?post=1409"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/dialer.one\/index.php\/wp-json\/wp\/v2\/tags?post=1409"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}